General information
Short description
Panel Mounting, Screw Connection
Long description
Panel Mounting, Screw Connection, Pitch:11.00mm, M4, 600V, 40A
Connection method
Screw Connection
Height (mm)
Refer to drawing
Number of positions
01P~16P
Material information
Insulation material group
Ⅲa
Flame retardant rating , compliant with UL94
V2
Insulation resistance
≥1000MΩ at DC 500V
Conductor material
COPPER ALLOY
Plating of conductor surface
Tin PLATED
Connection data-IEC
Rated voltage (III/3)(V)
630
Rated impulse voltage (III/3)(KV)
8
Conductor cross section solid. min (mm²)
0.34
Conductor cross section solid.max (mm²)
6
Conductor cross section stranded. min (mm²)
0.34
Conductor cross section stranded. max (mm²)
6
2 conductors with same cross section, solid, max (mm²)
6
2 conductors with same cross section, stranded, max (mm²)
6
Philips screwdriver size
PH2
Rated torque (N.m)
1.2~1.5
Recommend tightening torque. min (N.m)
1.2
Recommend tightening torque. max (N.m)
1.5
Tightening torque with flange. max (N.m)
0.8
Stripping Length (mm)
13~14The stripping length depends on the specification provided by the cablelug manufacturer
Mounting rail
TS-35N、TS-35/15N
End cover plate required
YES
Connection data-UL
Rated voltage (UL/CUL Group B)(V)
600
Rated current (UL/CUL Group B)(A)
40
Rated voltage (UL/CUL Group C)(V)
600
Rated current (UL/CUL Group C)(A)
40
Rated voltage (UL/CUL Group D)(V)
600
Rated current (UL/CUL Group D)(A)
40
Min. solid wire connection (AWG) acc. to UL/CUL
22
Max. solid wire connection AWG acc. to UL/CUL
8
Min. stranded wire connection AWG acc. to UL/CUL
22
Max. stranded wire connection AWG acc. to UL/CUL
8
Environment & Safety
Back of the hand protection (YES or NO)
YES
Finger protection (YES or NO)
NO
Operating temperature. max (°C)
125
Operating temperature. min (°C)
-40
UL Recognized
Wire Range (Group B)(AWG)
22-8
Rated voltage (Group B)(V)
600
Rated current (Group B)(A)
40
Wire Range (Group C)(AWG)
22-8
Rated voltage (Group C)(V)
600
Rated current (Group C)(A)
40
Wire Range (Group D)(AWG)
22-8
Rated voltage (Group D)(V)
600
Rated current (Group D)(A)
40
CUL Recognized
Wire Range (Group B)(AWG)
22-8
Rated voltage (Group B)(V)
600
Rated current (Group B)(A)
40
Wire Range (Group C)(AWG)
22-8
Rated voltage (Group C)(V)
600
Rated current (Group C)(A)
40
Wire Ranget (Group D)(AWG)
22-8
Rated voltage (Group D)(V)
600
Rated current (Group D)(A)
40
DKBC10-1000
Cover
For DKB10 / DKB20 / DKB30 / DKBB10 / DKBB20. Using UL94-V2 class of insulation material.
Add
TM-R100
Continuous Flat Marking Labels
Add
CSK11-40XX-A
Insertion bridge
For DKU40, DKUP40-XXPK, DKB40N, DKB40N-XXPCK. Material is copper alloy then tin-plated on surface.
Add
The web catalog is for reference only. Dinkle remains the right of product modification and engineering change of the design. The final product is made according to engineering drawing.