General information
Short description
Barrier terminals blocks, Panel Mounting
Long description
Barrier terminals blocks, Panel Mounting, Pitch : 8.80mm, M3, 600V, 15A
Connection method
Screw connection
Type of locking
Panel Mounting
Number of positions
02P~12P
Material information
Insulation material group
IIIa
Flame retardant rating , compliant with UL94
V2
Insulation resistance
≥1000MΩ at DC 500V
Conductor material
Copper Alloy
Plating of conductor surface
Ni plated
Connection data-IEC
Rated voltage (III/3)(V)
800
Rated impulse voltage (III/3)(KV)
8
Conductor cross section solid. min (mm²)
0.34
Conductor cross section solid.max (mm²)
2.5
Conductor cross section stranded. min (mm²)
0.34
Conductor cross section stranded. max (mm²)
2.5
2 conductors with same cross section, solid, max (mm²)
2.5
2 conductors with same cross section, stranded, max (mm²)
2.5
Slotted screwdriver size (Blade thickness x Width)(mm)
0.8x4.0
Philips screwdriver size
PH2
Recommend tightening torque. min (N.m)
0.5
Recommend tightening torque. max (N.m)
0.6
Stripping Length (mm)
7~8
Mounting rail
TS-35N、TS-35/15N
End cover plate required
YES
Connection data-UL
Rated voltage (UL/CUL Group B)(V)
600
Rated current (UL/CUL Group B)(A)
15
Rated voltage (UL/CUL Group C)(V)
600
Rated current (UL/CUL Group C)(A)
15
Min. solid wire connection (AWG) acc. to UL/CUL
22
Max. solid wire connection AWG acc. to UL/CUL
14
Min. stranded wire connection AWG acc. to UL/CUL
22
Max. stranded wire connection AWG acc. to UL/CUL
14
Environment & Safety
Back of the hand protection (YES or NO)
YES
Finger protection (YES or NO)
NO
Operating temperature. max (°C)
125
Operating temperature. min (°C)
-40
UL Recognized
Wire Range (Group B)(AWG)
22-14
Rated voltage (Group B)(V)
600
Rated current (Group B)(A)
15
Wire Range (Group C)(AWG)
22-14
Rated voltage (Group C)(V)
600
Rated current (Group C)(A)
15
CUL Recognized
Wire Range (Group B)(AWG)
22-14
Rated voltage (Group B)(V)
600
Rated current (Group B)(A)
15
Wire Range (Group C)(AWG)
22-14
Rated voltage (Group C)(V)
600
Rated current (Group C)(A)
15
CSK02-10XX-A
Insertion bridge
For DKBB10, DKBB10-XXPCK. Material is copper alloy then tin-plated on surface.
Add
CSK02-10XX-B
Insertion bridge
For DKBB10, DKBB10-XXPCK. Material is copper alloy then tin-plated on surface.
Add
DKBBC10-1000
Cover
For DKBB10 / DKBB20. Using UL94-V2 class of insulation material.
Add
DKBC10-1000
Cover
For DKB10 / DKB20 / DKB30 / DKBB10 / DKBB20. Using UL94-V2 class of insulation material.
Add
DKBK10-10P
Label
For DKB1. White color. Using UL94-V2 class of insulation material.
Add
TM-R100
Continuous Flat Marking Labels
Add
CSK01-10XX-B
Insertion bridge
For DKBB10, DKBB10-XXPCK. Material is copper alloy then tin-plated on surafce.
Add
CSK01-10XX-A
Insertion bridge
For DKBB10, DKBB10-XXPCK. Material is copper alloy then tin-plated on surface.
Add
The web catalog is for reference only. Dinkle remains the right of product modification and engineering change of the design. The final product is made according to engineering drawing.