Cell phone menu

町洋,插拔式端子台、印刷電路板式端子台、軌道式端子台、柵板式端子台、免螺絲式端子台、面板螺絲固定式端子台等系列產品

DP6-PE

DIN Rail Terminal BlocksPush-in Design

Yellow/&/Green(default)

AccessoriesPDF Download Inquiry Add

  • General information
    • Short description
    • DIN Rail terminal blocks , Push-in design Terminal Block
    • Long description
    • DIN Rail terminal blocks , Push-in design , Yellow/&/Green color
    • Category
    • Push-in Design Terminal Block
    • Color
    • Yellow/&/Green(default)
    • Connection method
    • Grounding Terminal Block
    • Type of locking
    • Rail Mounting
    • Length (mm)
    • 8
    • Width (mm)
    • 57.8
    • Height (mm)
    • 41.7
    • Level
    • Single level
    • Connection points
    • 2
  • Material information
    • Insulation material
    • PA
    • Insulation material group
    • I
    • Flame retardant rating , compliant with UL94
    • V0
    • Insulation resistance
    • ≥500MΩ at DC 500V
  • Connection data-IEC
    • Rated voltage (V)
    • 1000
    • Rated impulse voltage (III/3)(KV)
    • 8
    • Conductor cross section solid. min (mm²)
    • 0.5
    • Conductor cross section solid.max (mm²)
    • 10
    • Conductor cross section stranded. min (mm²)
    • 0.5
    • Conductor cross section stranded. max (mm²)
    • 6
    • Conductor cross section flexible, with min ferrule without plastic sleeve (mm²)
    • 0.5
    • Conductor cross section flexible, with max ferrule without plastic sleeve (mm²)
    • 6
    • Conductor cross section flexible, with min ferrule with plastic sleeve (mm²)
    • 0.5
    • Conductor cross section flexible, with max ferrule with plastic sleeve (mm²)
    • 6
    • 2 conductors with same cross section flexible, min twin ferrules with plastic sleeve (mm²)
    • 0.5
    • 2 conductors with same cross section flexible, max twin ferrules with plastic sleeve (mm²)
    • 1.5
    • Slotted screwdriver size (Blade thickness x Width)(mm)
    • 1.0X5.5
    • Stripping Length (mm)
    • 13
    • Mounting rail
    • TS-35
    • End cover plate required
    • YES
    • Grounding connections
    • YES
  • Connection data-UL
    • Rated voltage (UL/CUL Group B)(V)
    • 600
    • Rated voltage (UL/CUL Group C)(V)
    • 600
    • Min. solid wire connection (AWG) acc. to UL/CUL
    • 20
    • Max. solid wire connection AWG acc. to UL/CUL
    • 8
    • Min. stranded wire connection AWG acc. to UL/CUL
    • 20
    • Max. stranded wire connection AWG acc. to UL/CUL
    • 8
  • Environment & Safety
    • Back of the hand protection (YES or NO)
    • YES
    • Finger protection (YES or NO)
    • YES
    • Operating temperature. max (°C)
    • 120
    • Operating temperature. min (°C)
    • -40
  • UL Recognized
    • Wire Range (Group B)(AWG)
    • 20~8
    • Rated voltage (Group B)(V)
    • 600
    • Wire Range (Group C)(AWG)
    • 20~8
    • Rated voltage (Group C)(V)
    • 600
  • CUL Recognized
    • Wire Range (Group B)(AWG)
    • 20~8
    • Rated voltage (Group B)(V)
    • 600
    • Wire Range (Group C)(AWG)
    • 20~8
    • Rated voltage (Group C)(V)
    • 600
  • VDE Approval
    • Wire Range (mm²)
    • 0.5~6
    • Rated voltage (V)
    • 1000
  • TS-35

    DIN-Rail

    For DP / DP-PE / DK / DK-PE / AK / AK-PE / AK..P series.
    Material is iron.
    Length of 1000mm / 2000mm.
  • Add
  • TM44W

    Making Label

    For
    BEST APPLICATION:
    DP6, DP6-TN, DP6-TR, DP6-PE, DP6-TN-PE, DP6-TR-PE, DPTD6, DPTL6,
    DPTD6-D05, DPTD6-D06, DK6S

    AVAILABLE APPLICATION:
    DK4N-TF(5X20), DK4N-TFL(5X20), DKK4-TF(5X20)

    White color.
    Using UL94-V2 class of insulation material.
  • Add
  • TM49W

    Making Label

    For
    BEST APPLICATION:
    DP6, DP6-TN, DP6-TR, DP6-PE, DP6-TN-PE, DP6-TR-PE, DPTD6, DPTL6,
    DPTD6-D05, DPTD6-D06, DK6N, DK6N-TN, DK6N-PE, DKTD6N, DKTD6, DKTL6,
    PM6N

    AVAILABLE APPLICATION:
    DK10N, DK10N-TN, DK10N-PE, DK10-PE, DK16-PE, DK16N-PE, DK16H, DK35H,
    DK35H-PE, DK50, DK50-PE, DK95-PE, DK95, DK150, DK240
    DKM5, DKM6, DKM8, DKM10, DKM12, DKMW8, DKM6-2, DKM8-2, DKM10-2, SS4,
    SS5, SS6, SS7, SS8, SS11

    White color.
    Using UL94-V2 class of insulation material.
  • Add