General information
Short description
Three level Feed-Through Terminal Block
Long description
Three level Feed-Through Terminal Block, Screw Connection, Width:6.1mm, M2.5, 600V, 20A
Category
Three level Feed-Through Terminal Block
Connection method
Screw Connection
Type of locking
Rail mounting
Material information
Insulation material group
I
Flame retardant rating , compliant with UL94
V0
Insulation resistance
≥500MΩ at DC 500V
Plating of conductor surface
Tin PLATED
Connection data-IEC
Rated voltage (III/3)(V)
1000
Rated impulse voltage (II/2)(KV)
8
Rated impulse voltage (III/2)(KV)
8
Rated impulse voltage (III/3)(KV)
8
Conductor cross section solid. min (mm²)
0.34
Conductor cross section solid.max (mm²)
4
Conductor cross section stranded. min (mm²)
0.34
Conductor cross section stranded. max (mm²)
2.5
Conductor cross section flexible, with min ferrule without plastic sleeve (mm²)
0.5
Conductor cross section flexible, with max ferrule without plastic sleeve (mm²)
2.5
Conductor cross section flexible, with min ferrule with plastic sleeve (mm²)
0.5
Conductor cross section flexible, with max ferrule with plastic sleeve (mm²)
2.5
2 conductors with same cross section, solid, min (mm²)
0.34
2 conductors with same cross section, solid, max (mm²)
1.5
2 conductors with same cross section, stranded, min (mm²)
0.5
2 conductors with same cross section, stranded, max (mm²)
1.5
2 conductors with same cross section flexible, with min ferrule without plastic sleeve (mm²)
0.5
2 conductors with same cross section flexible, with max ferrule without plastic sleeve (mm²)
1.5
2 conductors with same cross section flexible, min twin ferrules with plastic sleeve (mm²)
0.5
2 conductors with same cross section flexible, max twin ferrules with plastic sleeve (mm²)
1.5
Slotted screwdriver size (Blade thickness x Width)(mm)
0.6x3.5
Philips screwdriver size
PH1
Recommend tightening torque. min (N.m)
0.4
Recommend tightening torque. max (N.m)
0.5
Stripping Length (mm)
9~11
Mounting rail
TS-35N/TS-35/15N
End cover plate required
YES
Connection data-UL
Rated voltage (UL/CUL Group B)(V)
600
Rated current (UL/CUL Group B)(A)
20
Rated voltage (UL/CUL Group C)(V)
600
Rated current (UL/CUL Group C)(A)
20
Rated voltage (UL/CUL Group D)(V)
600
Rated current (UL/CUL Group D)(A)
5
Min. solid wire connection (AWG) acc. to UL/CUL
22
Max. solid wire connection AWG acc. to UL/CUL
12
Min. stranded wire connection AWG acc. to UL/CUL
22
Max. stranded wire connection AWG acc. to UL/CUL
12
Environment & Safety
Back of the hand protection (YES or NO)
YES
Finger protection (YES or NO)
YES
Operating temperature. max (°C)
120
Operating temperature. min (°C)
-40
TM47LW
Marking Label
For BEST APPLICATION: DP2.5N Series, DP2.5N-3L-SPE, DPH2.5 Series, AK2.5 Series, DKES1.5N2, DKES1.5N3, DK2.5N Series, DKK2.5N Series, DK2.5N-3L Series AVAILABLE APPLICATION: DKES1.5, DK2.5-PE White color. Using UL94-V0 class of insulation material.
Add
The web catalog is for reference only. Dinkle remains the right of product modification and engineering change of the design. The final product is made according to engineering drawing.