General information
						 
					  
					   
														        
									  Short description 
									  Component terminal block, Push-in Design 
									 
							 
							 							        
									  Long description 
									  Component terminal block,Push-in Design, Width : 5.10mm, 300V, 20A 
									 
							 
							 							        
									  Category 
									  Component terminal block 
									 
							 
							 							        
							 
							 							        
									  Connection method 
									  Push-in Design 
									 
							 
							 							        
									  Type of locking 
									  Rail Mounting 
									 
							 
							 							        
							 
							 							        
							 
							 							        
									  Height (mm) 
									  46/ 47.5 (TS-35N),55(TS-35/15N) 
									 
							 
							 							        
							 
							 							        
							 
							 						   
						 
				
									   
					   
					 
					   Material information
						 
					  
					   
														        
							 
							 							        
									  Insulation material group 
									  I 
									 
							 
							 							        
									  Flame retardant rating , compliant with UL94 
									  V0 
									 
							 
							 							        
									  Insulation resistance 
									  ≧500MΩ at DC 500V 
									 
							 
							 						   
						 
				
									   
					   
					 
					   Connection data-IEC
						 
					  
					   
														        
							 
							 							        
							 
							 							        
									  Rated voltage (III/3)(V) 
									  500 
									 
							 
							 							        
									  Rated impulse voltage (III/3)(KV) 
									  6 
									 
							 
							 							        
									  Conductor cross section solid. min (mm²) 
									  0.14 
									 
							 
							 							        
									  Conductor cross section solid.max (mm²) 
									  4 
									 
							 
							 							        
									  Conductor cross section stranded. min (mm²) 
									  0.14 
									 
							 
							 							        
									  Conductor cross section stranded. max (mm²) 
									  2.5 
									 
							 
							 							        
									  Conductor cross section flexible, with min ferrule without plastic sleeve (mm²) 
									  0.25 
									 
							 
							 							        
									  Conductor cross section flexible, with max ferrule without plastic sleeve (mm²) 
									  2.5 
									 
							 
							 							        
									  Conductor cross section flexible, with min ferrule with plastic sleeve (mm²) 
									  0.25 
									 
							 
							 							        
									  Conductor cross section flexible, with max ferrule with plastic sleeve (mm²) 
									  2.5 
									 
							 
							 							        
									  2 conductors with same cross section flexible, min twin ferrules with plastic sleeve (mm²) 
									  0.5 
									 
							 
							 							        
									  2 conductors with same cross section flexible, max twin ferrules with plastic sleeve (mm²) 
									  0.5 
									 
							 
							 							        
									  Slotted screwdriver size (Blade thickness x Width)(mm) 
									  0.6X3.5 
									 
							 
							 							        
							 
							 							        
									  Mounting rail  
									  TS-35N、TS-35/15N 
									 
							 
							 							        
									  End cover plate required  
									  YES 
									 
							 
							 							        
							 
							 						   
						 
				
									   
					   
					 
					   Connection data-UL
						 
					  
					   
														        
									  Rated voltage (UL/CUL Group B)(V) 
									  300 
									 
							 
							 							        
									  Rated current (UL/CUL Group B)(A) 
									  20 
									 
							 
							 							        
									  Rated voltage (UL/CUL  Group C)(V) 
									  300 
									 
							 
							 							        
									  Rated current (UL/CUL Group C)(A) 
									  20 
									 
							 
							 							        
									  Min. solid wire connection (AWG) acc. to UL/CUL 
									  26 
									 
							 
							 							        
									  Max. solid wire connection AWG acc. to UL/CUL 
									  12 
									 
							 
							 							        
									  Min. stranded wire connection AWG acc. to UL/CUL 
									  26 
									 
							 
							 							        
									  Max. stranded wire connection AWG acc. to UL/CUL 
									  12 
									 
							 
							 						   
						 
				
									   
					   
					 
					   Environment & Safety
						 
					  
					   
														        
									  Back of the hand protection  (YES or NO) 
									  YES 
									 
							 
							 							        
									  Finger protection (YES or NO) 
									  YES 
									 
							 
							 							        
									  Operating temperature. max (°C) 
									  120 
									 
							 
							 							        
									  Operating temperature. min (°C) 
									  -40 
									 
							 
							 						   
						 
				
					
               
             
            
             
            
           
          
      
		  
		  
          
		  
          
          
          
          
            
              
              			           
						
						 
						
						  DSD01-2.5XXN
						 
						  Plug-in bridge
						   For DP2.5N Series, DPP2.5N Series, DP2.5N-3L Series, DP2.5SG Series, DPES2.5, DPES2.5-PE, DKD10-P001, DPHD10-P001, DPD16-P001, DPD10-P001, DPH2.5 Series, DPPES2.5, DPPES2.5-PE, AK2.5 Series, AKK2.5, AKK2.5-D01, AKK2.5-D02, AKK2.5-D03, AKK2.5-D04, AKK2.5-PV Red color. Using UL94-V0 class of insulation material.						 
						Add  
					   
			  			           
						
						 
						
						  TM42LW
						 
						  Marking Label
						   For  BEST APPLICATION: DP2.5N Series, DP2.5N-3L-SPE, DPH2.5 Series, AK2.5 Series, DKES1.5N2, DKES1.5N3, DPP2.5N Series, DP2.5N-3L, DP2.5N-3L-PV, DP2.5N-3L-L3PE, DP2.5N-3L-PE, DPH1.5SGU, DK2.5S, DK1.5SG Series, PM2.5N-XXP, PM2.5WN-XXP, PMM2.5WN-XXP, AKK2.5, AKK2.5-PV, AKK2.5-PE, AKK2.5-D Series, DK2.5L-3L, DK2.5P AVAILABLE APPLICATION: DPES2.5, DPES2.5-PE, DP2.5PG, DP2.5SG Series, DPPES2.5, DPPES2.5-PE White color. Using UL94-V0 class of insulation material.						 
						Add  
					   
			  			           
						
						 
						
						  TS-35
						 
						  DIN-Rail
						   For DP / DK..N / DK.. / AK / DKB / DKU.. /DKM..  series. Material is iron. Length of 1000mm / 2000mm.						 
						Add  
					   
			  			           
						
						 
						
						  0208-E001
						 
						  Spacer
						   For DPH2.5 Series, DP2.5N Series, DPP2.5N Series, DPD10-P001, DKD10-P001, DPHD10-P001, DPD16-P001, DP2.5SG, DP2.5SG-L24*, DP2.5SGT, DP2.5SGT-L24*, DP2.5SG, DP2.5SG-L24*, DP2.5SGR, DP2.5SGR-L24*, DP2.5SGRT, DP2.5SGRT-L24*, DPES2.5, DPPES2.5, DPES2.5-PE, DPPES2.5-PE, DP2.5N-T, AK2.5 Series Red color. Using UL94-V0 class of insulation material.						 
						Add  
					   
			  			           
						
						 
						
						  TS-35/15
						 
						  DIN-Rail
						   For DK / DK-PE series. Material is iron. Length of 1000mm / 2000mm.						 
						Add  
					   
			  			           
						
						 
						
						  0208-T001
						 
						  Test Plug
						   For  DPH2.5 Series, DP2.5N Series, DPP2.5N Series, DPD10-P001, DKD10-P001, DPHD10-P001, DPD16-P001, DP2.5SG, DP2.5SG-L24*, DP2.5SGT, DP2.5SGT-L24*, DP2.5SG, DP2.5SG-L24*, DP2.5SGR, DP2.5SGR-L24*, DP2.5SGRT, DP2.5SGRT-L24*, DPES2.5, DPPES2.5, DPES2.5-PE, DPPES2.5-PE, DP2.5N-T, AK2.5 Series Red color. Using UL94-V0 class of insulation material.						 
						Add  
					   
			  			           
						
						 
						
						  TM-R100
						 
						  Continuous Flat Marking Labels
						   						 
						Add  
					   
			  			           
						
						 
						
						  DPP2.5C
						 
						  End Cover
						   For DPP2.5 Beige color. Using UL94-V0 class of insulation material.						 
						Add  
					   
			  			           
						
						 
						
						  DSD06-2.5XXXT
						 
						  Plug-in  bridge
						   For DP2.5N Series, DPP2.5N Series, DP2.5N-3L Series, DP2.5SG Series, DPES2.5 Series, DPD10-P001, DKD10-P001, DPHD10-P001, DPD16-P001, DPH2.5 Series, AK2.5 Series, AKK2.5 Series, DPPES2.5, DK2.5L-3L Red color. Using UL94-V0 class of insulation material.						 
						Add  
					   
			  			           
						
						 
						
						  MKP-502
						 
						  Label
						   For DPP Series, AKK Series. Using UL94-V0 class of insulation material.						 
						Add  
					   
			               
           
		  
          
           
          
         
       
       
     The web catalog is for reference only. Dinkle remains the right of product modification and engineering change of the design. The final product is made according to engineering drawing.