General information
Short description
PCB Terminal Blocks, Push-in Design
Long description
PCB Terminal Blocks, Push-in Design, Reflow Soldering , Pitch:5.08mm, 300V, 12A
Category
PCB Terminal Blocks
Connection method
Push in Design
Soldering method
Reflow Soldering (Temperature condition according to standard IPC/JEDEC J-STD-020E)
Length (mm)
5.08*(P-1)+4.2
Pin demensions (Thickness x Width)(mm)
0.35x0.7
PCB hole diameter (mm)
1.0~1.1
Number of positions
02P~24P
Material information
Insulation material
HIGH-TEMPERATURE PLASTICS
Insulation material group
IIIa
Flame retardant rating , compliant with UL94
V0
Insulation resistance
≥500MΩ at DC 500V
Conductor material
COPPER ALLOY
Plating of conductor surface
Tin PLATED
Connection data-IEC
Rated voltage (II/2)(V)
500
Rated voltage (III/2) (V)
320
Rated voltage (III/3)(V)
250
Rated impulse voltage (II/2)(KV)
4
Rated impulse voltage (III/2)(KV)
4
Rated impulse voltage (III/3)(KV)
4
Conductor cross section solid. min (mm²)
0.14
Conductor cross section solid.max (mm²)
1.5
Conductor cross section stranded. min (mm²)
0.14
Conductor cross section stranded. max (mm²)
1.5
Conductor cross section flexible, with min ferrule without plastic sleeve (mm²)
0.25
Conductor cross section flexible, with max ferrule without plastic sleeve (mm²)
1.5
Conductor cross section flexible, with min ferrule with plastic sleeve (mm²)
0.25
Conductor cross section flexible, with max ferrule with plastic sleeve (mm²)
1.5
Slotted screwdriver size (Blade thickness x Width)(mm)
0.4x2.5
Stripping Length (mm)
8~9
Connection data-UL
Rated voltage (UL/CUL Group B)(V)
300
Rated current (UL/CUL Group B)(A)
12
Rated voltage (UL/CUL Group D)(V)
300
Rated current (UL/CUL Group D)(A)
12
Min. solid wire connection (AWG) acc. to UL/CUL
28
Max. solid wire connection AWG acc. to UL/CUL
14
Min. stranded wire connection AWG acc. to UL/CUL
28
Max. stranded wire connection AWG acc. to UL/CUL
14
Environment & Safety
Finger protection (YES or NO)
YES
Operating temperature. max (°C)
120
Operating temperature. min (°C)
-40
UL Recognized
Wire Range (Group B)(AWG)
28~14
Rated voltage (Group B)(V)
300
Rated current (Group B)(A)
12
Wire Range (Group D)(AWG)
28~14
Rated voltage (Group D)(V)
300
Rated current (Group D)(A)
12
CUL Recognized
Wire Range (Group B)(AWG)
28~14
Rated voltage (Group B)(V)
300
Rated current (Group B)(A)
12
Wire Ranget (Group D)(AWG)
28~14
Rated voltage (Group D)(V)
300
Rated current (Group D)(A)
12
The web catalog is for reference only. Dinkle remains the right of product modification and engineering change of the design. The final product is made according to engineering drawing.