General information
Short description
PCB Terminal Blocks, Push-in Design
Long description
PCB Terminal Blocks, Push-in Design, Pitch :15.00, 1000V, 101A
Category
PCB Terminal Blocks
Connection method
Push-in Design
Type of locking
With mounting flange
Soldering method
Wave soldering
Pin demensions (Thickness x Width)(mm)
1.5x1.8
PCB hole diameter (mm)
2.8
Number of positions
01~06P
Material information
Insulation material group
I
Flame retardant rating , compliant with UL94
V0
Insulation resistance
≥500MΩ at DC 500V
Conductor material
COPPER ALLOY
Plating of conductor surface
Tin PLATED
Connection data-IEC
Rated voltage (II/2)(V)
1000
Rated voltage (III/2) (V)
1000
Rated voltage (III/3)(V)
1000
Rated impulse voltage (II/2)(KV)
8
Rated impulse voltage (III/2)(KV)
8
Rated impulse voltage (III/3)(KV)
8
Conductor cross section solid. min (mm²)
2.5
Conductor cross section solid.max (mm²)
35
Conductor cross section stranded. min (mm²)
2.5
Conductor cross section stranded. max (mm²)
25
Conductor cross section flexible, with min ferrule without plastic sleeve (mm²)
2.5
Conductor cross section flexible, with max ferrule without plastic sleeve (mm²)
35
Conductor cross section flexible, with min ferrule with plastic sleeve (mm²)
2.5
Conductor cross section flexible, with max ferrule with plastic sleeve (mm²)
35
Philips screwdriver size
1x5.5
Tightening torque with flange. max (N.m)
0.5
Stripping Length (mm)
24~26
Connection data-UL
Rated voltage (UL/CUL Group B)(V)
600
Rated current (UL/CUL Group B)(A)
101
Rated voltage (UL/CUL Group C)(V)
600
Rated current (UL/CUL Group C)(A)
101
Rated voltage (UL/CUL Group D)(V)
600
Rated current (UL/CUL Group D)(A)
5
Min. solid wire connection (AWG) acc. to UL/CUL
14
Max. solid wire connection AWG acc. to UL/CUL
2
Min. stranded wire connection AWG acc. to UL/CUL
14
Max. stranded wire connection AWG acc. to UL/CUL
2
Environment & Safety
Operating temperature. max (°C)
120
Operating temperature. min (°C)
-40
UL Recognized
Wire Range (Group B)(AWG)
14~2
Rated voltage (Group B)(V)
600
Rated current (Group B)(A)
101
Wire Range (Group C)(AWG)
14~2
Rated voltage (Group C)(V)
600
Rated current (Group C)(A)
10
Wire Range (Group D)(AWG)
14~2
Rated voltage (Group D)(V)
600
Rated current (Group D)(A)
5
CUL Recognized
Wire Range (Group B)(AWG)
14~2
Rated voltage (Group B)(V)
600
Rated current (Group B)(A)
101
Wire Range (Group C)(AWG)
14~2
Rated voltage (Group C)(V)
600
Rated current (Group C)(A)
101
Wire Ranget (Group D)(AWG)
14~2
Rated voltage (Group D)(V)
600
Rated current (Group D)(A)
5