Cell phone menu

町洋,插拔式端子台、印刷電路板式端子台、軌道式端子台、柵板式端子台、免螺絲式端子台、面板螺絲固定式端子台等系列產品

TKE04

PCB Terminal BlocksTransformer Terminal Blocks

Pitch : 7.50 mm, M3, 600V, 25sol/30str

AccessoriesPDF Download Inquiry Add

CAD data

  • General information
    • Short description
    • Transformer terminal blocks, Screw connection
    • Long description
    • Transformer terminal block, Screw connection, Pitch : 7.50 mm, M3, 600V, 25sol/30str
    • Pitch (mm)
    • 7.5
    • Color
    • Green (default)
    • Connection method
    • Screw connection
    • Type of locking
    • Without
  • Material information
    • Insulation material
    • PA
    • Insulation material group
    • I
    • Flame retardant rating , compliant with UL94
    • V0
    • Conductor material
    • COPPER ALLOY
    • Plating of conductor surface
    • Tin PLATED
  • Connection data-IEC
    • Rated voltage (V)
    • 630
    • Rated current (A)
    • 25/30
    • Rated voltage (III/3)(V)
    • 630
    • Rated impulse voltage (II/2)(KV)
    • 5
    • Rated impulse voltage (III/2)(KV)
    • 5
    • Screw thread
    • M3
    • Slotted screwdriver size (Blade thickness x Width)(mm)
    • 0.8x4.0
    • Philips screwdriver size
    • PH1
    • Rated torque (N.m)
    • 0.53
    • Stripping Length (mm)
    • 15~17
  • Connection data-UL
    • Rated voltage (UL/CUL Group B)(V)
    • 600
    • Rated current (UL/CUL Group B)(A)
    • 25/30
    • Rated voltage (UL/CUL Group C)(V)
    • 600
    • Rated current (UL/CUL Group C)(A)
    • 25/30
    • Rated voltage (UL/CUL Group D)(V)
    • 600
    • Rated current (UL/CUL Group D)(A)
    • 5
    • Min. solid wire connection (AWG) acc. to UL/CUL
    • 30
    • Max. solid wire connection AWG acc. to UL/CUL
    • 10
    • Min. stranded wire connection AWG acc. to UL/CUL
    • 30
    • Max. stranded wire connection AWG acc. to UL/CUL
    • 10
  • Environment & Safety
    • Back of the hand protection (YES or NO)
    • YES
    • Finger protection (YES or NO)
    • YES
    • Operating temperature. max (°C)
    • 115
    • Operating temperature. min (°C)
    • -40
  • UL Recognized
    • Wire Range (Group B)(AWG)
    • 10~30
    • Rated voltage (Group B)(V)
    • 600
    • Rated current (Group B)(A)
    • 30
    • Wire Range (Group C)(AWG)
    • 10~30
    • Rated voltage (Group C)(V)
    • 600
    • Rated current (Group C)(A)
    • 30
    • Wire Range (Group D)(AWG)
    • 10~30
    • Rated voltage (Group D)(V)
    • 600
    • Rated current (Group D)(A)
    • 5
  • CUL Recognized
    • Wire Range (Group B)(AWG)
    • 10~30
    • Rated voltage (Group B)(V)
    • 600
    • Rated current (Group B)(A)
    • 30
    • Wire Range (Group C)(AWG)
    • 10~30
    • Rated voltage (Group C)(V)
    • 600
    • Rated current (Group C)(A)
    • 30
    • Wire Ranget (Group D)(AWG)
    • 10~30
    • Rated voltage (Group D)(V)
    • 600
    • Rated current (Group D)(A)
    • 5
  • VDE Approval
    • Rated voltage (V)
    • 630
    • Rated current (A)
    • 25/30
  • TKE-R-XX

    Rail

    Rail
  • Add

The web catalog is for reference only. Dinkle remains the right of product modification and engineering change of the design. The final product is made according to engineering drawing.